Shipwiring/Offshore Screened
Instrumentation Cables to BS6883
(Ref. 658 SW4 Instrumentation)
Manufactured in both pairs and triples these 150/250V
instrumentation cables provide collective or individual screening through
the use of metallic foils and drain wires. Offering good flexibility for
installation in confined spaces or where difficult routing is necessary,
the galvanised steel wire braid provides mechanical protection.
The latest
SW4 Low Smoke Halogen Free sheathing compounds are used to ensure that
in the event of a fire the cables offer excellent protection to both people
and property by not emitting toxic or corrosive gases.
|
|
Cable Construction -
Individually screened
Tinned copper wire conductors to BS 6360, class 2 or
class 5, EPR insulation, cores twisted into pairs or triples, each pair/triple
foil screened with a tinned copper drain wire, LSHF inner sheath, galvanised
steel wire braid, SW4 LSHF outer sheath - grey or blue.
Cable Construction -
Collectively screened
Tinned copper wire conductors to BS 6360, class 2 or
class 5, EPR insulation, cores twisted into pairs or triples, overall
foil screen and a tinned copper drain wire, LSHF inner sheath, galvanised
steel wire braid, SW4 LSHF outer sheath - grey or blue.
|

|
Core Identification
| Pairs : |
Each pair black, white and numbered |
| Triples : |
Each triple black, white, red and numbered |
| (Alternative colour codes are available) |
Technical Information
| Voltage rating |
150/250V |
| Conductors |
Tinned, BS6360 class 2 or
class 5 |
| Temperature rating |
+90°C maximum conductor temperature |
| Static temperature rating |
-30°C to +90°C |
| Bending radius (static) |
8 x cable O/D |
| Flame retardant |
IEC60332 part 3A, BS4066 part 3A |
Fire resistant versions to IEC60331 are also available, ref BS7917 |