BS5839 : 1 & BS6387 CWZ Fire Alarm Cables, Standard Grade

Now widely used in fire alarm systems and to feed emergency lighting. The FSC range of fire survival cables and accessories offers a cost effective alternative to MICC for many applications. Supplied in red, black or white on 100m and 500m reels as standard.

Special versions with other sheath colours or core combinations are available to order. The cable can also be printed with your name, message or installation details subject to availability.


 
We are able to offer many brands including Draka Firetuf, IDH Kilflam 2000, Prysmian (Pirelli) FP200 Gold, Nexans Pyrolyon E and Alsecure ranges. Just specify when you call for a quote.

Construction

Plain copper conductor, circuit integrity Low Smoke Halogen Free insulation. Metallic barrier tape with copper earth-wire maintaining longitudinal contact. Low Smoke Halogen Free sheath.

Technical Information

Conductors Copper wire Class 1 to BS6360 for sections 1.0 & 1.5 mm²
Copper wire Class 2 to BS6360 for sections 2.5 & 4.0 mm²
Voltage 300V/500V
Resistance to Fire Alone IEC 60331 : 3 hours at 750°C
BS6387 Cat. C: 3 hours at 950°C
Resistance to Fire with Water BS6387 Cat. W: 15 mins at 650°C
Plus 15 mins with water spray
Resistance to Fire with
Mechanical Shock
BS6387 Cat. Z: 15 mins at 950°C
Approvals BASEC, LPCB, BS7629 : 1, BS8434-1
BS5839 : 1 2002 & BS EN 50200 PH30

Technical Data

Part No.
Cores
& mm²
Weight
Kg/Km
O/D
mm
 38701002   2E 1.0   80   8.0 
 38701003   3E 1.0   93   8.0 
 38700104   4E 1.0   120   9.0 
 38701502   2E 1.5   98   8.5 
 38701503   3E 1.5   121   9.5 
 38701504   4E 1.5   148   10.5 
 38702502   2E 2.5   139   10.5 
 38702503   3E 2.5   179   12.0 
 38702504   4E 2.5   205   13.0 

* W on the end of the part number changes the sheath colour from red to white,
B changes the sheath colour to black.

 

At FSC we refer to LSHF as Low Smoke Halogen Free

This term is interchangeable with LSZH (Low Smoke Zero Halogen), LSOH (Low Smoke Zero Halogen), OHLS (Zero Halogen Low Smoke) and FRNC (Flame Retardant Non-Corrosive). Beware of the terms LSF (Low Smoke and Fume) or RP (Reduced Propogation), when relating to signal or control cables will normally be modified PVC and produce 'Loads of Smoke and Fume'!

Fire retardant, fire resistant, flame resistant or flame retardant?

These terms are often misunderstood. Most cables when exposed to fire will not carry on functioning. If you require cable to continue working in the event of fire, and in accordance with various standards please call us.
Back to last page Return to TOP