DeviceNet™ Thick Cables

Designed for use on Allen Bradley DeviceNet™ systems, the “thick” cable construction incorporates a power and data pair for backbone wiring. Several sheathing options are available for different installation environments. These cables are also referred to as DeviceNet™ Trunk cables.

Allen Bradley DeviceNet™ is a Rockwell Automation system supported by ODVA.

 

Static cables

Power pair: Tinned copper conductors 15AWG (1.5mm² approx), PVC insulation, aluminium foil screen.

Data pair: Tinned copper conductors 18AWG (0.75mm² approx), foamed PE insulation, aluminium foil screen.

Lay-Up: Pairs laid up with a common 18AWG (0.75mm² approx) tinned copper drain wire, overall tinned copper wire braid – 65% optical coverage, PVC or CPE sheath.

 

Dynamic cables

Power pair: Tinned copper conductors 15AWG (1.5mm² approx), PE insulation, aluminium foil screen.

Data pair: Tinned copper conductors 18AWG (0.75mm² approx), foamed PE insulation, aluminium foil screen.

Lay-Up: Pairs laid up with a common 18AWG (0.75mm² approx) tinned copper drain wire, overall tinned copper wire braid – 65% optical coverage, PUR sheath.

 

Technical Information

Core identification Power pair: Black & Red
Data pair: Blue & White
Bending radius 7.5 x O.D. Fixed
15 x O.D. Flexing
Operating temperature -20°C to +70°C Fixed
0°C to +70°C Flexing
Conductor resistance Power pair: 11.8 Ω/km @ 20°C
Data pair: 22.6 Ω/km @ 20°C
Voltage Working : 300V
Impedance 100-120 Ω
Effective capacitance @ 1khz 40pF/m (data pair)
Velocity of propagation 75% (data pair)
Nominal attenuation kHz
125
500
1Mhz
dB/100m
0.4
0.8
1.2

Technical Data

Part No.
Belden
No.
Conductor
Stranding/mm

Power
Conductor
Stranding/mm

Data
Sheath
material
Sheath
colour
Weight
Kg/Km
O/D
mm
Application
  15ABDY    3082A   19/0.32   19/0.25   PVC   Grey    174   12.2   Static  
  15ABDR    3083A   19/0.32   19/0.25   CPE   Yellow    174   12.1   Static  
  15ABDYA     SWA   19/0.32   19/0.25   SWA/PE   Black   359   16.1   Static  
  15ABDY-HF    Hi-FLEX   84/0.15   40/0.18   PUR   Violet    209   12.1   Dynamic  

 

Fire retardant, fire resistant, flame resistant or flame retardant?

These terms are often misunderstood. Most cables when exposed to fire will not carry on functioning. If you require cable to continue working in the event of fire, and in accordance with various standards please call us.

 

 

 

 

 

 

 

 

 

 

 

 

 

Some common mispellings of Belden Cable include - Beldon, Beldan, Balden, Baldon and Beldin.

Back to last page Return to TOP